Why the outlet valve need to be closed when the first time of centrifugal pump started

Why the outlet valve need to be closed when the first time of centrifugal pump started.

Water pump Start closing pressure means when you start the centrifugal water pump at first time if there is no water in the pipeline,you ‘d better close the outlet pipe valve.
Why?because at the first time ,there is no water in the pipe,in the case of zero flow, the electric pump head is the highest,the power is minimum,With the opening of the outlet valve increased,the flow rate increases, the head decreases, and the power increases, efficiency increases maximum,If the outlet valve is fully opened at firt time , the flow of the pump may deviate from the rated flow , the water pump efficiency is also reduced a lot,
As a result, the shaft power is greater than the motor power, causing tripping or even burning the motor.Therefore, the operation rules of multistage centrifugal pumps require that the inlet valve be opened before starting, and the outlet valve shall be closed.However, the outlet valve closed time can not be too long, because at this time the liquid in the pump cycling, the liquid temperature gradually increased, easy to cause mechanical seals, due to lack of lubrication friction and wear or damage.
Gelaili pump industry provide you the best centrifugal water pump,company flagship product:booster pump,aquarium water pump,stainless steel ro booster pump,fire pump,coolant pump,shower pump,,dewatering pump.
More information,please visit:http://www.jxgllpump.com


评论

此博客中的热门博文

Why Ro booster pump in a water treatment system does not work?

Why Ro booster pump does not work?Let's find out the reason. Reverse Osmosis booster Pump is one of the key part of the RO water purification machine,we call it ro booster pump,It is a kind of booster pump be used in the reverse osmosis device, it has the function of self-priming and pressurization. Ro booster pump provide Ro membrane water pressure and water flow,to make Ro rembrane work. Ro membrane is another important component of the RO water purification machine.So Ro water purification machine can give us purifield water. Some times ro booster pump does not work,so the whole system is out of work,there are follow reasons cause the ro booster pump doesn't work: 1,Purifield water tank at a high level or the original water tank is at a low position. 2,Ro water pressure is higher than the protection switch Settings, the controller automatically switched on. 3,Ro booster pump suction pressure is lower than protection switch Settings, the controller automatically discon...

A centrifugal water pump show us your capability

In recent decades, China’s property market has entered a rising rapidly, the purchasing power exuberant state. However, due to the recent weakness in the market, the property market began to gradually slow down, into a stable, and even occasional decline stage. Recently, one of my friends suddenly called me and excitedly told me that he had taken a fancy to a house in the neighborhood,the real estate belongs to Poly property, it is said that the property just opened, it attracted many buyers of onlookers.in just a few days, the house has been sold out.My friend has been on the sidelines all the time, as he has a set of property, not anxious to buy second sets of houses,instead, he chose carefully and wanted to buy one sets around the good evironment,he wanted it is a quality and residential environment are both very good house.I don’t know why he has taken a fancy to this neighborhood recently. My friend was excited to invite me to go with him to purchase procedures,So, we came to t...

Causes of Electric Motor Burning by Water pump

1. First, find out whether the motor burns the bearing (mechanical fault) or the coil (electrical fault). If it is the fault of burning coil, it is mainly caused by overcurrent, sometimes too high or too low voltage will also cause the coil to heat and short circuit, so check that the voltage when running is too different from the rated voltage.There may be several reasons for over-current short-circuiting: A. the equipment is overloaded to make the motor run for a long time at rated or over rated current. In particular, the starting current of the motor is 3-5 times that of the rated current. Therefore, we should try to avoid running with load or full load when starting the equipment (mainly depending on the matching allowance of rated current and normal operating current of motor). B, the motor works in a wet working environment. The insulation of the coils should be checked before the motor starts. The insulation requirements of different voltage grades are also different. May r...