How to increase the self-priming capacity of the centrifugal water pump

First method(simplest one)
Self-priming sewage pump vacuum pump is arranged in the water pipeline, water pump start before the vacuum pump starts to pump water pipe Neixianbu
with water, to ensure that the water pump, quick start.
This type of water absorption requires a perfect automatic control system to ensure normal work.
Second method(more simple)
The self – priming pump reduces the water inlet pipe curve , the fall height and the horizontal interval.
Third way( Trouble, but it works.)
The self-priming pump is equipped with a water suction tank in front of the pump. In this way, a suction tank should be installed on the pump suction
pipe. Before the first operation of the pump, the tank should be filled with water manually, and after the first operation the tank should be
stopped. Since the intake pipe of the suction tank is higher than the water level inside the pipe,the water in the tank will not flow back into the
pool, so the water can be stored in the tank, and because the water suction tank outlet pipe (that is, the suction pipe of the pump) is lower than
the water level inside the pipe. Therefore, it can ensure that the water absorption pipe of the pump is covered with water, and when the pump is
running again, the water in the water tank is pumped away by the pump, and the water in the pool is added to the water absorption tank under the
action of atmospheric pressure. Enter the pump through the pipes in the tank tank.
The fourth way
Self-priming sewage pump suction pipe. The suction end of the valve is installed at the end of suction end of the valve is actually a check valve, it
can only guarantee the flow by the pool into the suction tube can not turn the clock back, so if the water pipe is full of water, despite the
elevation axis pump the water level above the pool, but because there is the role of the water suction end of the valve. The tube into the pool water
will not enable the suction tube has been filled with water to ensure the pump can automatically, quickly start.
The fifth way
In the pump structure , for example , the self – priming pump in the figure below directly combines the vacuum impeller with the centrifugal pump .

Jiangxi Gelaili pump industry co.,ltd produce centrifugal water pump,we have CDL,CDLF series,CHL,CHLF series stainless steel electric pump,can be used as ro booster pump, shower pump,fire pump,coolant pump,aquarium water pump and so on,we also supply cast iron pump,they are WQ series dewatering pumps,dirty water pump and GD series pipeline pump.
Gelaili pump industry co.,ltd supplies you competitive price and high quality products. 

评论

此博客中的热门博文

Why Ro booster pump in a water treatment system does not work?

Why Ro booster pump does not work?Let's find out the reason. Reverse Osmosis booster Pump is one of the key part of the RO water purification machine,we call it ro booster pump,It is a kind of booster pump be used in the reverse osmosis device, it has the function of self-priming and pressurization. Ro booster pump provide Ro membrane water pressure and water flow,to make Ro rembrane work. Ro membrane is another important component of the RO water purification machine.So Ro water purification machine can give us purifield water. Some times ro booster pump does not work,so the whole system is out of work,there are follow reasons cause the ro booster pump doesn't work: 1,Purifield water tank at a high level or the original water tank is at a low position. 2,Ro water pressure is higher than the protection switch Settings, the controller automatically switched on. 3,Ro booster pump suction pressure is lower than protection switch Settings, the controller automatically discon...

How to exclude the interference from the frequency converter

These problems often occur when you work at regular work and debug the equipment: 1 . When the converter of the heat exchange station is opened , the pressure transmitter shall jump ; 2 . using frequency converter to control the water supply , the voltage transformer is used as a signal for collecting pressure , and the voltage transformer is interfered by the frequency converter ; 3 . When the frequency converter starts up the motor , the voltage change signal is unstable and the jitter is great ; 4 . The voltage transformer ( 4 – 20mA ) shall jump after the frequency converter is started , and the integrated thermal resistance ( 4 – 20mA ) nearby is not affected , and the signal line is not shielded . These phenomena are due to the interference of the frequency converter. Why does the inverter produce interference The inverter comprises a rectifying circuit and an inverter circuit , wherein the input AC power is converted into a DC voltage through a rectifying circuit and a wave loo...

Difference between suction stroke and lift head of water pump

Pump self-priming capacity is also called maximum self suction height.It is the maximum height at which the water is pumped (the vertical distance between the pump and the the liquid surface to be pumped) without fill in water into the pump tunnel. General water level is lower than the location of the pump, you need to pump self-priming capacity.For example ,if we need to pump water from a river ,we will not plan pipe first,so we need a pump which has self-priming capacity. Or we need to pump some corrosive liquid,we can not fill water into the water pump tunnel. Some centrifugal water pumps do not have self-priming capacity,they need to fill in water at first time of using. The pump lift is the height that pump can lift water up.We usually expressed in H,the the unit is meter. The lift of the centrifugal pump is based on the center line of the impeller.The lift Consists of two parts,first is the vertical height from the center line of the pump impeller to the surface of the water s...