1. First, find out whether the motor burns the bearing (mechanical fault) or the coil (electrical fault). If it is the fault of burning coil, it is mainly caused by overcurrent, sometimes too high or too low voltage will also cause the coil to heat and short circuit, so check that the voltage when running is too different from the rated voltage.There may be several reasons for over-current short-circuiting: A. the equipment is overloaded to make the motor run for a long time at rated or over rated current. In particular, the starting current of the motor is 3-5 times that of the rated current. Therefore, we should try to avoid running with load or full load when starting the equipment (mainly depending on the matching allowance of rated current and normal operating current of motor). B, the motor works in a wet working environment. The insulation of the coils should be checked before the motor starts. The insulation requirements of different voltage grades are also different. May r...